Topbas Grup http://www.topbasgrup.com.tr Lightning Rod - Paratoner Fri, 04 Dec 2020 11:32:36 +0000 tr hourly 1 https://wordpress.org/?v=5.8 http://www.topbasgrup.com.tr/wp-content/uploads/2018/06/cropped-topbas_logo-32x32.png Topbas Grup http://www.topbasgrup.com.tr 32 32 IONIA ESE LIGHTNING ROD http://www.topbasgrup.com.tr/ionia-ese-lightning-rod/ Tue, 10 Dec 2019 08:23:00 +0000 http://www.topbasgrup.com.tr/?p=65 IONIA EARLY STREAMER EMISSION (ESE) SYSTEM PREMIUM QUALITY LIGHTNING ROD (CONDUCTOR)

> Active Lightning Rod unit has a feature of Early Streamer Emission system.

> ΔT of Ionia is 15/40/60 μs.

> Ionia Active Lightning Rod unit was tested in terms of such spesific quality control process’ like mechanical, electrical and environmental aspects and passed all of these quality tests successfully.

> International validity certification: NFC 17-102. Compatible fully with International standarts.

> Ionia was found as successful and premium quality products by Middle East Technical University after spesific examinations.

> Ionia was covered with durable special recin in order to resist harsh weather conditions.

> Lightning Rod’s Ion Generator was made of %100 stainless steel and placed inside of the rod’s body.

Does not corrode chemically.

> Adapt with Topbas Group Remote Test Module®.

> Buying Premium Quality Ionia, you are going to be under our full product guarantee for 10 years.

IONIA – ESE LIGHTNING ROD TECHNICAL SPECIFICATIONS

IONIA - Kim thu se phat xa som Tho Nhi Ky

  • Electronical Structure
  • NFC 17-102 Early Streamer
  • Suitable for corrosive environment
  • 304 L Stainless Steel (Inox) Material
  • No use of external battery
  • Lenght : 59cm / Net weight : 3.1 kg
  • Ion Unit Diameter : 125mm
  • Rod diameter : D20
  • Grounding mast diameter : 2″
  • Testable with external Topbas Tesst Device
  • 20 years warranty
  • CE Certifaction, ISO 9001 & 14001

PROTCTION RADIUS OF IONIA 60 RP (M):

Protection Levelh (m) Level ID=20m Level IID=30m Level IIID=45m Level IVD=60m
2 32 34 40 44
3 48 52 59 65
4 64 68 78 87
5 79 86 97 107
6 79 86 97 107
7 79 87 98 108
8 79 87 98 108
]]>
SIRIUS ESE LIGHTNING ROD http://www.topbasgrup.com.tr/sirius-ese-lightning-rod/ Thu, 14 Jun 2018 08:20:23 +0000 http://www.topbasgrup.com.tr/?p=63 SIRIUS EARLY STREAMER EMISSION (ESE) SYSTEM PREMIUM QUALITY LIGHTNING ROD (CONDUCTOR)

> Active Lightning Rod unit has a feature of Early Streamer Emission system.

> ΔT of Sirius is 65 μs.

> Sirius Active Lightning Rod unit was tested in terms of such spesific quality control process’ like mechanical, electrical and environmental aspects and passed all of these quality tests successfully.

International validity certification: NFC 17-102. Compatible fully with International standarts.

> Sirius was found as successful and premium quality products by Middle East Technical University after spesific examinations.

> Sirius was covered with durable special recin in order to resist harsh weather conditions.

> Lightning Rod’s Ion Generator was made of %100 stainless steel and placed inside of the rod’s body.

Does not corrode chemically.

> Adapt with Topbas Group Remote Test Module®.

> Buying Premium Quality Sirius, you are going to be under our full product guarantee for 10 years.

SIRIUS TECHNICAL SPECIFICATIONS

  • ESE AT (∆T) : 65µs
  • NFC 17-102 Early Streamer
  • Suitable for corrosive environment
  • 304 L Stainless Steel (Inox) Material
  • No use of external battery
  • Lenght : 60cm / Net weight : 3.2 kg
  • Ion Unit Diameter : 26 cm
  • Rod diameter : D20
  • Grounding mast diameter : 2″
  • Testable with external Topbas Tesst Device
  • 20 years warranty
  • CE Certifaction, ISO 9001 & 14001

PROTECTION SIRIUS

]]>
UMBRA ECO-15 LIGHTNING ROD http://www.topbasgrup.com.tr/umbra-eco-15-lightning-rod/ Thu, 14 Jun 2018 07:35:16 +0000 https://www.topbasgrup.com.tr/?p=122 UMBRA ECO-15 EARLY STREAMER EMISSION (ESE) SYSTEM PREMIUM QUALITY LIGHTNING ROD

> Active Lightning Rod unit has a feature of Early Streamer Emission system.

> ΔT of Umbra Eco-15 is 15 μs.

> Umbra Eco-15 Active Lightning Rod unit was tested in terms of such spesific quality control process’ like mechanical, electrical and environmental aspects and passed all of these quality tests successfully.

> International validity certification: NFC 17-102. Compatible fully with International standarts.

> Umbra Eco-15 was found as successful and premium quality products by Middle East Technical University after spesific examinations.

> Umbra Eco-15 was covered with durable special recin in order to resist harsh weather conditions.

> Lightning Rod’s Ion Generator was made of %100 stainless steel and placed inside of the rod’s body.

Does not corrode chemically.

> Adapt with Topbas Group Remote Test Module®.

> Buying Premium Quality Umbra Eco-15, you are going to be under our full product guarantee for 20 years.

UMBRA ECO-15 ESE lightning air terminal with the below technical parameters.

  • Stainless Steel material (304 L) – suitable for corrosive environements
  • ΔT = 15 micro seconds
  • METU lab tested as per NF C 17-102 (2011) standard
  • Lightning current = 100 KA (10/350 micro sec) tested
  • 20 years warranty
  • Protection Radius = 51 mtrs (Level IV / Standard)
]]>
SIRIUS-25 ESE LIGHTNING ROD http://www.topbasgrup.com.tr/sirius-25-ese-lightning-rod/ Thu, 14 Jun 2018 07:13:50 +0000 https://www.topbasgrup.com.tr/?p=118 SIRIUS-25 EARLY STREAMER EMISSION (ESE) SYSTEM PREMIUM QUALITY LIGHTNING ROD (CONDUCTOR)

> Active Lightning Rod unit has a feature of Early Streamer Emission system.

> ΔT of Sirius is 25 μs.

> Sirius Active Lightning Rod unit was tested in terms of such spesific quality control process’ like mechanical, electrical and environmental aspects and passed all of these quality tests successfully.

International validity certification: NFC 17-102. Compatible fully with International standarts.

> Sirius was found as successful and premium quality products by Middle East Technical University after spesific examinations.

> Sirius was covered with durable special recin in order to resist harsh weather conditions.

> Lightning Rod’s Ion Generator was made of %100 stainless steel and placed inside of the rod’s body.

Does not corrode chemically.

> Adapt with Topbas Group Remote Test Module®.

> Buying Premium Quality Sirius, you are going to be under our full product guarantee for 10 years.

SIRIUS-25 TECHNICAL SPECIFICATIONS

  • ESE AT (∆T) : 25µs
  • NFC 17-102 Early Streamer
  • Suitable for corrosive environment
  • 304 L Stainless Steel (Inox) Material
  • No use of external battery
  • Lenght : 60cm / Net weight : 3.2 kg
  • Ion Unit Diameter : 26 cm
  • Rod diameter : D20
  • Grounding mast diameter : 2″
  • Testable with external Topbas Tesst Device
  • 20 years warranty
  • CE Certifaction, ISO 9001 & 14001

PROTECTION RADIUS

]]>
LYRA-12 LIGHTNING ROD http://www.topbasgrup.com.tr/lyra-12-lightning-rod/ Wed, 13 Jun 2018 12:43:26 +0000 https://www.topbasgrup.com.tr/?p=133

LYRA-12 EARLY STREAMER EMISSION (ESE) SYSTEM PREMIUM QUALITY LIGHTNING ROD

> Active Lightning Rod unit has a feature of Early Streamer Emission system.

> ΔT of Lyra-12 is 10 μs.

> Lyra-12 Active Lightning Rod unit was tested in terms of such spesific quality control process’ like mechanical aspects and passed all of these quality tests successfully.

> International validity certification: NFC 17-102. Compatible fully with International standarts.

> Lyra-12 was found as successful and premium quality products by Middle East Technical University after spesific examinations.

> Lyra-12 was covered with durable special recin in order to resist harsh weather conditions.

> Lightning Rod’s Ion Generator was made of %100 stainless steel and placed inside of the rod’s body.

Does not corrode chemically.

> Adapt with Topbas Group Remote Test Module®.

> Buying Premium Quality Lyra-12, you are going to be under our full product guarantee for 20 years.

LYRA-12 ESE lightning air terminal with the below technical parameters.

  • Stainless Steel material (304 L) – suitable for corrosive environements
  • ΔT = 10 micro seconds
  • METU lab tested as per NF C 17-102 (2011) standard
  • Lightning current = 100 KA (10/350 micro sec) tested
  • 20 years warranty
  • Protection Radius = 51 mtrs (Level IV / Standard)

]]>
OUR QUALITY POLICY http://www.topbasgrup.com.tr/our-quality-policy/ Wed, 13 Jun 2018 08:07:00 +0000 http://www.topbasgrup.com.tr/?p=42 TO PROTECT AND RAISE COMPANY REPUTATION AND CREDIBILITY 
In order to provide the continuity of firm’s reputation gained after extensive efforts and raise it to a higher level, to deliver our projects on time and with quality without comprising our understanding of quality. To work more and with more care and meet the employer’s and customer’s requirements and expectations by identifying them on time in order to be a company that is sought after and preferred.

TO FOLLOW TECHNOLOGICAL AND SCIENTIFIC DEVELOPMENTS
In order to improve level of quality, monitor scientific and technological developments. To provide training which personnel and suppliers would need to learn occupational innovations and thus provide the continuous improvement of quality level.

PARTICIPATION OF ALL THE EMPLOYEES AND SUPPLIERS.. To value teamwork so that quality, productivity and increase of profitability are provided. To ensure awareness of functions and responsibilities of individuals in the organization so that highest quality level is attained in the company’s corporate structure and progress in work. To maintain control of the quality levels of sub teams worked together and ensure their participation in teamwork.

PERSONNEL SELECTION AND INTERNAL TRAINING
To accept as a company quality principle that accurate, productive and profitable ideas are borne from informed, experienced brainpower. In this regard, to have qualified people join the firm. To hire personnel appropriate for the qualifications in the corporate structure and not work according to the personnel.

PROTECTION OF THE NATURAL ENVIRONMENT
During the planning and conduct of work, to take measures that would minimize the impact on the environment. To create an effective environmental awareness and become an exemplifying company that would leave behind a more livable world to the future generations.

HEALTH AND WORK SAFETY OF THE EMPLOYEES
To care for employees’ health and work safety. To work in compliance with all the related written laws and regulations in all the work done.

]]>
VISION-MISSION http://www.topbasgrup.com.tr/vision-mission/ Wed, 13 Jun 2018 08:05:00 +0000 http://www.topbasgrup.com.tr/?p=40 OUR VISION

It is to become an exemplifying and a leading firm by acquiring “a trustable and established firm” identity through projects we would develop by internalizing quality and by being supplier to and solution partner with firms who have become brand names in domestic and international markets.

OUR MISSION

To provide professional solutions suitable for our customers’ needs and expectations in projects related to our areas of activity.

To follow the new construction materials in the world with a management understanding open to innovations and bring together quality, economy and esthetics parallel to the expectations of the era.

To provide customer satisfaction by adhering to principles of using right material, right application and timely delivery and to become a sought out firm in our sector.

To conduct work in a coordinated fashion with human resources composed of subject matter experts and experienced technical staff and plan the future with them.

To establish friendships which do not end after sales.

]]>
SIRIUS-40 ESE LIGHTNING ROD http://www.topbasgrup.com.tr/sirius-40-ese-lightning-rod/ Mon, 11 Jun 2018 07:54:10 +0000 https://www.topbasgrup.com.tr/?p=115 SIRIUS-40 EARLY STREAMER EMISSION (ESE) SYSTEM PREMIUM QUALITY LIGHTNING ROD (CONDUCTOR)

> Active Lightning Rod unit has a feature of Early Streamer Emission system.

> ΔT of Sirius is 40 μs.

> Sirius Active Lightning Rod unit was tested in terms of such spesific quality control process’ like mechanical, electrical and environmental aspects and passed all of these quality tests successfully.

International validity certification: NFC 17-102. Compatible fully with International standarts.

> Sirius was found as successful and premium quality products by Middle East Technical University after spesific examinations.

> Sirius was covered with durable special recin in order to resist harsh weather conditions.

> Lightning Rod’s Ion Generator was made of %100 stainless steel and placed inside of the rod’s body.

Does not corrode chemically.

> Adapt with Topbas Group Remote Test Module®.

> Buying Premium Quality Sirius, you are going to be under our full product guarantee for 10 years.

SIRIUS-40 TECHNICAL SPECIFICATIONS

  • ESE AT (∆T) : 40µs
  • NFC 17-102 Early Streamer
  • Suitable for corrosive environment
  • 304 L Stainless Steel (Inox) Material
  • No use of external battery
  • Lenght : 60cm / Net weight : 3.2 kg
  • Ion Unit Diameter : 26 cm
  • Rod diameter : D20
  • Grounding mast diameter : 2″
  • Testable with external Topbas Tesst Device
  • 20 years warranty
  • CE Certifaction, ISO 9001 & 14001

PROTECTION RADIUS

]]>
LIGHTNING EVENT COUNTER http://www.topbasgrup.com.tr/lightning-event-counter/ Fri, 01 Jun 2018 08:13:36 +0000 http://www.topbasgrup.com.tr/?p=48 STRIKER X LIGHTNING EVENT COUNTER

TOPBAS GRUP (Turkey) developed a robust lightning event counter. 6 digits non resettable electro mechanical display counter with the tetsing jack. The device is designed to count and record the lightning strikes captured by lightning protection systems such as ESE lightning rods, simple capturing rods and the cage method.

The lightning counter is necessary to determine whether the lightning rod received any lightning strikes.The counter is connected to the down conductor of the lightning arrester and therefore it detects the electromagnetic field caused by lightning discharge current, and it counts each strike and shows it by way of the number display.With the help of the lightning counter the customer can follow the number of lightning strikes arrested by your system. It does not require any additional power supply for its operation.

Striker X Lightning Event Counter

Display Model Electromechanical display (non re-settable)
Current Tested (10/350 µs) 100 kA
Start Sensitivity (8/20 µs) 1500 A
Current Sample Mode Inductive Probe (Built-in)
Indicator 6 digits
Operating temperature (oC) -20 ~ +85
Enclosure material Plastic
Degree of protection IP 67 (IEC 529)
Dimension of counter (cm) 16 (L) x 9 (W) x 6 (H)

FEATURES

• IP 67 rated enclosure suitable for external application.
• Ease of installation, Striker X can be retro-fitted to any lightning protection system.
• Non-intrusive and fast acting proximity circuit detects lightning transient currents.
• Non resettable electro-mechanical counter.
• Can be mounted at any location along the down conductor.

OUR COUNTERS

]]>
LIGHTNING COUNTER TESTER http://www.topbasgrup.com.tr/lightning-counter-tester/ Fri, 01 Jun 2018 08:10:02 +0000 http://www.topbasgrup.com.tr/?p=44

To test the counting function of the lightning event counter / lightning strike counter, a battery operated impulse current emitting lightning counter tester is deisgned and developed by TOPBAS GRUP (Turkey)

This will ensure the customers that the counters are in working condition. When the push button is pressed, impulse current passes inside the counter and the counting gets increased thus confirming the proper functioning of the counter.

Operation of the lightning arrester
When rain clouds form at the top of the structure where the lightning rod is formed, the negative charges on the lower side of these formed clouds push the negative charges in the lightning rod and send them to the ground with copper wire. Subsequently, There is a single plus load at the end of the lightning rod. The plus loads remaining at the tip of the lightning rod also spew upward and neutralize the negative loads in the rain clouds. It prevents the lightning from falling by making it ineffective.

OUR TESTER

]]>